Miniaturization is achieved by built-in antenna with ceramic multilayer structure and mounted IC inside cavity.
Appearance | |||
---|---|---|---|
Dimensions | 5.0x2.0x1.5mm | 6.0x3.0x1.7mm | |
Read | 250mW | ~ 8cm | ~ 10cm |
1W | ~35cm | ~ 60cm | |
Memory | EPC | 128/96bits | 128bits |
User | 32/64bits | 512bits | |
Note | Suitable for metallic products |
* Measurement condition of read distance : UHF tag is attached on the center of 200x200x0.5mm Cu plate.
Read distance may depend on performance of reader, such as power, antenna size etc., usage environment and how RFID tag is used or attached to object.
( Image of attachment on surgical instruments )
Contents of test | Condition | Results |
---|---|---|
High temperature storage |
+175°C 1,000 hours |
OK |
Low temperature storage |
-65°C 1,000 hours |
OK |
Temperature cycle |
-40°C to +160°C 1,000 cycles |
OK |
High temperature high humidity bias |
85°C85%RH 1,000 hours |
OK |
* Based on Kyocera testing environment. Does not guarantee communication results for all usage environments.
Contents of test | Condition | Results |
---|---|---|
Boiling water |
100°C / 48 hours |
OK |
Brine (5%) | 48 hours | OK |
Na-carbonate aqueous solution (5%) |
48 hours |
OK |
Ethanol |
48 hours |
OK |
Methanol |
48 hours |
OK |
MEK (Methyl Ethyl Ketone) |
48 hours |
OK |
Toluene | 48 hours | OK |