Stacks and Units

Power controller series

Return to the listing

Single phase AC power contoller series

Zero-cross ON/OFF control

Applications
Adjustment heater temperature of semiconductor diffusion furnace and curving glass furnace heater
Features
Zero-cross ON/OFF control, Phase angle control
Input open collector
Heater break alarm
Thyristor short-circuit alarm
Thyristor one side ignition alarm
Full-open structure
Part naming
AS 20 07 PU2 - 4
Part naming 1Number of circuits: 4 circuits
Part naming 2Function (PU1: break alarm / break alarm + fuse)
Part naming 3Rating current: 70[A] (1/10 size description)
Part naming 4Voltage: 200[V] (1/10 size description)
Part naming 5Series
  • Connection diagram
    Connection diagram
  • outline
    outline
AC input voltage input voltage range(V) Output current (A) Part number Diagram Cooling Device Device blocking voltage(V) W×H×D(mm)

AC200/
220V
180~240 70 AS2007PU2-4   Self-cooling PDT1008 800 260×340×230
180~240 100 AS2010PU2-4   Wind-cooling PDT1008 800 260×340×230
180~240 150 AS2015PU2-3   Wind-cooling PDT1008 800 260×340×230
180~240 200 AS2020PU2-3   Wind-cooling PDT1508 800 260×362×230

AC400/
440V
370~480 65 AS4007PU2-4   Self-cooling PDT10016 1600 260×340×230
370~480 100 AS4010PU2-3   Wind-cooling PDT6016 1600 260×365×230
370~480 150 AS4015PU2-3   Wind-cooling PDT10016 1600 260×365×230
370~480 200 AS4020PU2-3   Wind-cooling PDT15016 1600 260×387×230

Peripheral temperature 40℃
all air cooling buit-in fan(AC200V)

Return to the listing

Three phase AC power controller series

Zero-cross ON/OFF control

Applications
For adjusting heater temperature by using phase angle control
Features
Almost no erroneous motion by power supply noise. Able to use it to induction load.
Input control
Variable resistance: 1KΩB
Current command: 4-20mA
Voltage command: 1-5V
Control function
Elevation configuration
Slope(Gain) configuration
Shutdown
Fuse break alarm
Soft start
Control function
Please select as a option.
A: Current regulator function/ Stablize output current of load variation and voltage when controlling.
L: Current limiter/ controls output current not to exceed the setting level.
  • Three phase AC power controller series
  • Connection diagram
    Connection diagram
AC input voltage input voltage range(V) AC output current(A) Part number Diagram Cooling Device Device blocking voltage(V) W×H×D(mm)

AC200/
220V
180~240 50 CTNA2005   Self-cooling PDT1008 800 360×430×300
180~240 100 CTNA2010   Self-cooling PDT1508 800 360×430×300
180~240 150 CTNA2015   Wind-cooling PDT1508 800 360×430×350
180~240 200 CTNA2020   Wind-cooling PDT2008 800 460×515×320
180~240 300 CTNA2030   Wind-cooling PDT400N8 800 460×515×340
180~240 400 CTNA2040   Wind-cooling PDT400N8 800 460×525×375
180~240 500 CTNA2050   Wind-cooling 553PA80 800 520×475×450
180~240 700 CTNA2070   Wind-cooling 1503PA80 800 710×650×550

AC400/
440V
370~480 50 CTNA4005   Self-cooling PDT10016 1600 360×430×300
370~480 100 CTNA4010   Self-cooling PDT15016 1600 360×430×300
370~480 150 CTNA4015   Self-cooling PDT15016 1600 360×430×350
370~480 200 CTNA4020   Wind-cooling PDT20016 1600 460×515×320
370~480 300 CTNA4030   Wind-cooling PDT400N16 1600 460×515×340
370~480 400 CTNA4040   Wind-cooling PDT400N16 1600 460×525×375
370~480 500 CTNA4050   Wind-cooling 553PA160 1600 520×475×450
370~480 700 CTNA4070   Wind-cooling 1503PA160 1600 710×650×550

Output current according to the peripheal tempature of 40℃
all air cooling buit-in fan(AC200V)

Return to the listing

DC power controller

Zero-cross ON/OFF control

Applications
For adjusting heater temperature. Adjustment of field generator.
Features
Almost no erroneous motion by power supply noise. Able to use it to induction load.
  • Connection diagram
    Connection diagram
AC input voltage input voltage range(V) DC output current(A) Part number Diagram Cooling Device Device blocking voltage(V) W×H×D(mm)

AC200/
220V
180~240 50 DTNA2005   Self-cooling PDT608 800 360×420×300
180~240 100 DTNA2010   Self-cooling PDT1508 800 360×420×300
180~240 200 DTNA2020   Wind-cooling PDT1508 800 360×420×350
180~240 300 DTNA2030   Wind-cooling PDT2008 800 460×515×320
180~240 400 DTNA2040   Wind-cooling PDT400N8 800 460×515×340
180~240 500 DTNA2050   Wind-cooling PDT400N8 800 460×525×375

AC400/
440V
370~480 50 DTNA4005   Self-cooling PDT6016 1600 360×420×300
370~480 100 DTNA4010   Self-cooling PDT15016 1600 360×420×300
370~480 200 DTNA4020   Wind-cooling PDT15016 1600 360×420×350
370~480 300 DTNA4030   Wind-cooling PDT20016 1600 460×515×320
370~480 400 DTNA4040   Wind-cooling PDT400N16 1600 460×515×340
370~480 500 DTNA4050   Wind-cooling PDT400N16 1600 460×525×375

Output current according to the peripheal tempature of 40℃
all air cooling buit-in fan(AC200V)

Return to the listing